| Technical Specification |
Ballast lumen factors for control gear incorporating Perferm™ technology |
(suitable
for all lamps including low Mercury & Amalgam lamps) |
| Module Number |
Lamp
T8/T12
|
Lamp
T5 |
T5 Circular
|
Lamp 2D
|
Lamp
TC-L |
Lamp
TC-S/E |
Lamp TC-D/E
|
Lamp TC-T/E
Amalgam |
|||
No
of cells |
|
|
|
|
|
l |
|
||||
| 18W18W | 18W18W | 18W18W | 18W18W | 18W |
20W |
30W |
36W |
40W |
58W |
70W |
100W |
8W |
14W |
21W |
24W |
28W |
35W |
39W |
49W |
54W |
80W |
22W |
40W |
55W |
16W |
21W |
28W |
38W |
55W |
18W |
24W |
34W |
36W |
40W |
55W |
5W |
7W |
9W |
11W |
10W |
13W |
18W |
26W |
13W |
18W |
26W |
32W |
42W |
57W |
| PH4003P3 | PL4003P3 | PLR5003P3 | 18W18W | 3 x 4Ah |
12 |
12 |
9 |
9 |
9 |
24 |
16 |
13 |
12 |
13 |
20 |
22 |
23 |
20 |
20 |
29 |
12 |
|||||||||||||||||||||||||||||
| PH4005P3 | PL4005P3 | PLR5005P3 | 4 x 4Ah |
11 |
11 |
10 |
10 |
10 |
20 |
11 |
11 |
18 |
13 |
12 |
12 |
25 |
26 |
24 |
26 |
29 |
17 |
16 |
||||||||||||||||||||||||||||
| MT5414P3 | 4 x 4Ah |
32 |
||||||||||||||||||||||||||||||||||||||||||||||||
| PH4007P3 | PL4007P3 | PLR5007P3 | 4 x 4Ah |
10 |
11 |
9 |
9 |
11 |
13 |
12 |
||||||||||||||||||||||||||||||||||||||||
| PH4403P3 | PL4403P3 | PLR5403P3 | 4 x 4Ah |
23 |
16 |
|||||||||||||||||||||||||||||||||||||||||||||
| PH4418P3 | PL4418P3 | PLR5418P3 | 4 x 4Ah |
25 |
25 |
42 |
32 |
40 |
37 |
38 |
40 |
|||||||||||||||||||||||||||||||||||||||
| PH4009P3 | PL4009P3 | PLR5009P3 | 5 x 4Ah |
13 |
13 |
13 |
11 |
24 |
29 |
14 |
15 |
14 |
11 |
33 |
||||||||||||||||||||||||||||||||||||
| PH4506P3 | PL4506P3 | PLR5506P3 | 5 x 4Ah |
28 |
25 |
26 |
30 |
28 |
25 |
22 |
23 |
22 |
20 |
|||||||||||||||||||||||||||||||||||||
| PH4011P3 | PL4011P3 | PLR5011P3 | 5 x 4Ah |
10 |
7 |
11 |
9 |
10 |
11 |
|||||||||||||||||||||||||||||||||||||||||
| MT5528P3 | 5 x 4Ah |
28 |
25 |
26 |
||||||||||||||||||||||||||||||||||||||||||||||
| PHR5607P3 | 6 x 4Ah |
18 |
18 |
18 |
16 |
13 |
14 |
20 |
||||||||||||||||||||||||||||||||||||||||||
| PHR5608P3 | 6 x 4Ah |
11 |
10 |
12 |
12 |
|||||||||||||||||||||||||||||||||||||||||||||
| PHR5809P3 | 8 x 4Ah |
15 |
14 |
9 |
27 |
24 |
20 |
17 |
30 |
15 |
18 |
|||||||||||||||||||||||||||||||||||||||
| MT5854P3 | 8 x 4Ah |
27 |
24 |
20 |
17 |
|||||||||||||||||||||||||||||||||||||||||||||
| PHR5108P3 | 10 x 4Ah |
17 |
10 |
10 |
11 |
13 |
||||||||||||||||||||||||||||||||||||||||||||
| MT5108P3 | 10 x 4Ah |
10 |
Ballast lumen factors for
emergency control gear (not suitable for low Mercury and Amalgam
lamps) |
|
Module Number |
Lamp T8/T12 |
Lamp
T5 |
T5
Circular |
Lamp 2D
|
Lamp
TC-L |
Lamp
TC-S/E |
Lamp
TC-D/E |
Lamp
TC-T/E Amalgam |
|||
No
of cells |
|
|
|
|
|
|
|
||||
| 18W18W | 18W18W | 18W18W | 18W18W | 18W |
20W |
30W |
36W |
40W |
58W |
70W |
100W |
8W |
14W |
21W |
24W |
28W |
35W |
39W |
49W |
54W |
80W |
22W |
40W |
55W |
16W |
21W |
28W |
38W |
55W |
18W |
24W |
34W |
36W |
40W |
55W |
5W |
7W |
9W |
11W |
10W |
13W |
18W |
26W |
13W |
18W |
26W |
32W |
42W |
57W |
| M2019/3(NM) | MS2020/3(M3) | 18W18W | 2
x 4Ah |
26 |
||||||||||||||||||||||||||||||||||||||||||||||
| M2001P3(NM) | 3
x 4Ah |
24 |
34 |
|||||||||||||||||||||||||||||||||||||||||||||||
| MS2001P3 | MH4001P3 | ML4001P3 | 3 x 4Ah |
24 |
24 |
34 |
25 |
22 |
28 |
20 |
23 |
33 |
||||||||||||||||||||||||||||||||||||||
| MS2003P3 | MH4003P3 | ML4003P3 | 3 x 4Ah |
14 |
14 |
14 |
17 |
|||||||||||||||||||||||||||||||||||||||||||
| MS2007P3 | MH4007P3 | ML4007P3 | 4 x 4Ah |
12 |
10 |
29 |
21 |
14 |
13 |
13 |
||||||||||||||||||||||||||||||||||||||||
| MS2011P3 | MH4011P3 | ML4011P3 | 5 x 4Ah |
13 |
13 |
10 |
9 |
14 |
21 |
14 |
13 |
13 |
18 |
|||||||||||||||||||||||||||||||||||||
| Perferm™ technology is an ongoing development involving the latest lamp technology and as such is subject to change as and when further lamps/data become available. | |
We
strongly recommend that modules incorporating Perferm™ technology
are used in all emergency luminaires and conversions to provide the ultimate
future proofing against lamp evolution. |
|
| Most modules and PCB's are tested and approved to EN60924/EN60925. They are EMC compliant to EN55015 and carry the British Standard Kitemark and CE mark. | |
| They incorporate over temperature and charger short circuit protection. | |
| Mains supply 230V - 6% + 10% 50/60Hz power consumption 8VA (other supply Voltages available on request). | |
| Output circuitry uses a high efficiency sinusodial inverter, with nominal operating current of 1 Amp. | |
| Available as standard in 3 hour operation (other durations to order). | |
| All modules have battery over discharge protection as standard (DDP) to prevent discharge below 1 Volt per cell. | |
| Reverse battery polarity protected. | |
| All connections are via terminal blocks with a green light emitting diode (LED), to indicate correct charging conditions. All products are supplied with LED indicators. | |
| Operating temperature range module 0 to 70°C (centre side of case) | |
| Printed circuit boards 0 to 90°C (coil/core of charging transformer) | |
| All ballast lumen factors are shown as worst case. | |
| All products listed above are for 3 hours duration | |
| All figures are based on an ambient temperature of 25°C. |
Fixing Centre |
![]() |
|