PALS™ - Addressable Emergency Lighting
Regular testing and maintenance of emergency lighting systems is essential and is now a legal requirement in many countries. It is possible to carry out testing manually but this can be expensive and time consuming and accurate reports of test results and system events. It ensures,building owners and occupiers are informed promptly of any problems effecting the emergency lighting system and as the system can be networked and remotely accessed, off site monitoring also becomes an option.
   
Key features include:
Each PALS panel is fully expandable from 1 to 5 loops using plug-in line drivers
126 devices can be supported by each line driver card allowing one panel to monitor and test 360 devices
A total of 95 PALS panels can then be networked to allow a total system size of 58,850 devices
A range of interface units allow the system to operate with most types of emergency luminaires including self-contained, central battery and static inverter systems
User friendly software with auto device learn and data loop status for trouble free setting up, commisioning and fault finding
  Constant communication with luminaires to prove system integrity
Reports charger or mains supply failure within 60 seconds of the event
  Loops, zones and luminaires can be disabled to carry out maintenance work
 
Carries out daily, weekly, quarterly and annual tests - fully automatically - or to customers requirements
 
Full system and luminaires test can be manually activated at any time
  Reports luminaire number, location and nature of the fault detected
 
On-board power supplies on the panel to maintain memory if power fails
  Designed to fail safe whatever event occurs
 
Easy to use, tab style questions for programming and operating, On-board alpha numeric keyboard for easy updates and modifications
  External printer available
 
Multi panel networking, modem communications and PC report and control
  Complies with the requirements of PR/EN62034
 
Specifications PALS™ Control Panel OEL-CA1
 
Dimensions: Height 350 x Width 340 x depth 115mm
Weight: 10Kg (ex. Batteries)
Mains Supply: 230V 50Hz AC - other voltages are available
Standby: Integral charger for 12V, 6Ah Sealed lead acid battery (battery not included)
Warning Output: 4 programmable short circuit protected monitored outputs
  1 amp per output maximum, total current 2 amps
Auxilliary relay: 2 programmable volt free change over outputs over outputs
  Contacts rated at 5 amps 250V max. per relay
Sensor Circuit: 2 wire addressable loop
Loop Protection: Short circuit protection on-board (i.e. without isolators in loop)
Signalling Lines: 1 expandable to 5 via plug-in line driver circuits
Devices per Line: up to 126 luminaires per line driver
Controls: Alpha-numeric key paid
Indicators: 20 Test zone LEDs and audible buzzer
Display: 2 line by 40 characters backlit LCD
  20 LED zone test indicators
  20 LED zone fault indicators
  10 LED system indicators
  2 LED common fault indicators
Communications: 1xRS485 serial port (OEL-485 plug in module required)
  1xon-board RS232 port (OEL-004 lead assembly required)
Recommended Cable: For signalling line circuits: Neldon 8762, 8760 or 8719 is recommended.