PALS™ -
Addressable Emergency Lighting |
||
![]() |
Regular
testing and maintenance of emergency lighting systems is essential and
is now a legal requirement in many countries. It is possible to carry
out testing manually but this can be expensive and time consuming and
accurate reports of test results and system events. It ensures,building
owners and occupiers are informed promptly of any problems effecting
the emergency lighting system and as the system can be networked and
remotely accessed, off site monitoring also becomes an option. |
|
Key
features include: |
||
|
Each PALS
panel is fully expandable from 1 to 5 loops using plug-in line drivers |
||
| 126 devices can be supported by each line driver card allowing one panel to monitor and test 360 devices | ||
| A total of 95 PALS panels can then be networked to allow a total system size of 58,850 devices | ||
A range of interface
units allow the system to operate with most types of emergency luminaires
including self-contained, central battery and static inverter systems |
||
User friendly software
with auto device learn and data loop status for trouble free setting
up, commisioning and fault finding |
||
| Constant communication with luminaires to prove system integrity | ||
| Reports charger or mains supply failure within 60 seconds of the event | ||
| Loops, zones and luminaires can be disabled to carry out maintenance work | ||
Carries
out daily, weekly, quarterly and annual tests - fully automatically - or
to customers requirements |
||
Full
system and luminaires test can be manually activated at any time |
||
| Reports luminaire number, location and nature of the fault detected | ||
On-board
power supplies on the panel to maintain memory if power fails |
||
| Designed to fail safe whatever event occurs | ||
Easy
to use, tab style questions for programming and operating, On-board
alpha numeric keyboard for easy updates and modifications |
||
| External printer available | ||
Multi
panel networking, modem communications and PC report and control |
||
| Complies with the requirements of PR/EN62034 | ||
Specifications
PALS™ Control Panel OEL-CA1 |
||
| Dimensions: | Height 350 x Width 340 x depth 115mm | |
| Weight: | 10Kg (ex. Batteries) | |
| Mains Supply: | 230V 50Hz AC - other voltages are available | |
| Standby: | Integral charger for 12V, 6Ah Sealed lead acid battery (battery not included) | |
| Warning Output: | 4 programmable short circuit protected monitored outputs | |
| 1 amp per output maximum, total current 2 amps | ||
| Auxilliary relay: | 2 programmable volt free change over outputs over outputs | |
| Contacts rated at 5 amps 250V max. per relay | ||
| Sensor Circuit: | 2 wire addressable loop | |
| Loop Protection: | Short circuit protection on-board (i.e. without isolators in loop) | |
| Signalling Lines: | 1 expandable to 5 via plug-in line driver circuits | |
| Devices per Line: | up to 126 luminaires per line driver | |
| Controls: | Alpha-numeric key paid | |
| Indicators: | 20 Test zone LEDs and audible buzzer | |
| Display: | 2 line by 40 characters backlit LCD | |
| 20 LED zone test indicators | ||
| 20 LED zone fault indicators | ||
| 10 LED system indicators | ||
| 2 LED common fault indicators | ||
| Communications: | 1xRS485 serial port (OEL-485 plug in module required) | |
| 1xon-board RS232 port (OEL-004 lead assembly required) | ||
| Recommended Cable: | For signalling line circuits: Neldon 8762, 8760 or 8719 is recommended. | |
luminaire emergency lighting ballast exit sign orbik spel fire central battery gear detection pcb can baton freznel ip65 ip52 ip50 ip20 ip25 maintained uk UK