| Simple and Easy to Install Fire Alarm System Using Only a Pair of Wires |
![]() |
Our two-conventional fire alarm system is installed using only one pair of wires, eliminating the need for a dedicated sounder circuit. The panel differentiates between a call point and detector alarm and can accommodate 32 devices per zone. The two-wire panel also features a fault monitoring display for each zone a one man walk test facility and zones are configured without the need to use resistors or capacitors on unused zones. With the increasing number of new buildings and with greater pressure on environmental officers to actively enforce the requirements of BS5839 part 6 (The code of practice for fire detection and alarm systems in dwellings) organisations are constantly looking for a reliable early warning fire system without the disruption of nuisance alarms. To satisfy this ever increasing market, the two-wire plus system has been developed. Both systems incorporate the multi-point detector, which offers 7 modes of detection and can be supplied with an integral 90dBA sounder. This greatly simplifies the installation as one device suits all applications. Also available are user-friendly contractor kits, consisting of either a 2 zone or 4 zone panel, six multi-function devices, two call points and a detector/sounder head removal tool. |
| Features | |
Two-wire
installation - Only one circuit per zone to connect detectors, call points
and sounders, therefore reducing installation costs |
|
| Call point identification. The panel has the ability to differentiate between call point and detector alarms | |
| System fully complies with BS5839 and EN54 | |
| Can support up to 32 devices per zone | |
| 72 hour standby | |
| All panels have 1 auxiliary sounder circuit | |
| Detector head contamination warning - Before going into false alarm, the panel will indicate which zone and device require a replacement optical chamber | |
Includes
all system features plus:- |
|
| Programmable delay (1-5 minute) | |
| Local sounder operates while detector alarm is confirmed | |
| Full alarm when fire is confirmed | |
| Immediate full alarm when fire is detected in communal areas | |
| Eliminates the disruption of nuisance alarms | |
| The perfect solution of BS5938 Part 6 (HMO's) | |
| Ordering Codes |
| Cat No | Description |
| FP-020 | Duplex Two-Wire 2 Zone Conventional Fire Panel |
| FP-018 | Duplex Two-Wire 4Zone Conventional Fire Panel |
| FP-019 | Duplex Two-Wire 8 Zone Conventional Fire Panel |
| FP-021 | Duplex Plus Two-Wire 2 Zone Conventional Fire Panel |
| FP-022 | Duplex Plus Two-Wire 4 Zone Conventional Fire Panel |
| FP-023 | Duplex Plus Two-Wire 8 Zone Conventional Fire Panel |
| FP-024 | Duplex Two-Wire 2 Zone Contractor Kit |
| FP-025 | Duplex Two-Wire 4 Zone Contractor Kit |
| FPA-1017 | Duplex Two-Wire 8 Zone Contractor Kit |
| FPA-1019 | Duplex Panel Keys and Barrel for 8 Zone Panel |

| Technical Information |
Number of Zone Circuits: |
2 Zone, 4 Zone and 8 Zone |
| Auxiliary Sounder Circuit: | One |
| Mains Supply Voltage: | 230 Volts ac + 10%, 15% 50Hz |
| System Voltage: | 24 Volts dc |
| System Indicators: | Detector Alarm, Call Point Alarm & Fault |
| Maximum Zone Loading:: | 32 Detectors, Unlimited Call Points |
| Required Batteries:* | 2 x 12V 2.1Ah (8 Zone 2 x 12V 3.2Ah) |
| Dimensions (mm): | 310 x 243 x 85 (8 Zone 315 x 400 x90) |
| Panel Construction: | Fire Retardant Plastic (8 Zone Mild Steel) |
| Batteries to be ordered separately | |